2.4 GHz. Step 1: Use your phone to scan the QR code to download and register the Solis Cloud APP. It came with a Ginlong data logger wifi stick that I have set up according to the instructions. Ginlong Solis(Stock Code: 300763.SZ) is one of the oldest and largest global string inverter specialists, that manufactures string inverters for converting DC to AC power and interacting with utility grid, which help reduce the carbon footprint of human s Please follow the process for installing a new data logger. on solis S3-WIFI WiFi Stick Datalogger Installation Guide, solis GPRS Stick Datalogger Instruction Manual. No-Grid - El inversor no reconoce la red. Please follow the instructions below: Step3: Use your mobile phone to send a text message to the SIM card in the stick. You can learn more about what kind of cookies we use, why, and how from our Privacy policy. No-Grid - El inversor no reconoce la red. Hi all, The AutoSave Draft feature is now disabled across the site. I used to have problems like that all the time until I got a wifi mesh system in the house. Solis WIFI Stick Troubleshooting TOP 5 Issues: 1. The scripts will process data from the WiFi and LAN Data . Copyright@2020 Ginlong Technologies All rights reserved. Simple connectivity has your Solis solar system online in just a few steps delivering ongoing comprehensive data analysis and fault finding anytime, anywhere. it tries to reconnect itself vut you can just unplug it and plug it back. Enter the password for the network and then tap "Next". Go to your web browser - Input 10.10.100.254 4. Select Network, fill in the IP address assigned by the router/network administrator, Let us know how can we improve this article! app on your phone. In order to verify this go to Network and look at connected Inverter. Router has a firewall blocking the data 5. Hi Everyone, I got some help with the Ginlong Wifi and I have been able to set the system up and log onto the Ginlong monitoring websitebut the system says it is 'loading' but no data is shown on the site. Monitoring Accessory Configured But Still Won't Link? I've been in contact with the team at . The decision to disable the feature was made via a poll last year. Scan the bar code on the logger [note: a cellular logger is shown in the photo but it has the same scanning process as the, You should see a message that says "Bound Successfully" and now you will need to set up the logger on the local, settings and then connecting to the network that starts with "AP" - this is the. I have set up an account on Ginlongmonitoring.com and entered the details of the data logger. You will need to have the, Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. According to the website my data logger is offline. With permission, you can test the firewall by removing the firewall for 5 minutes to see if the communication with the remote server changes to pingable. We use cookies to try and give you a better experience in Freshdesk. Once you've connected to the "AP" network, return toSolisCloudand then look for the home network that you wish to connect the logger to. This article is a guide for how to replace a Solis Data Logger on an existing system: one that has already been created in SolisCloud. If you have not already been registered onSolisCloud, please see Step 18:SolisCloudMonitoring Platform. *, We appreciate your effort and will try to fix the article. AC Voltage Offset Procedure and Firmware Requirements, Service - Modbus Issues - Troubleshooting, LCD Protective Sticker Replacement Procedure. This is to (1) ensure you have the correctWiFipassword and (2) ensure there is a strong enoughWiFisignal at the inverter for there to be a stable connection. Have contacted the company who sold me it. AC Voltage Offset Procedure and Firmware Requirements, Service - Modbus Issues - Troubleshooting, LCD Protective Sticker Replacement Procedure. Yes Firmware Version: 3.16.9. i have recently installed a solar inverter which has a data logger > having an issue connecting it to my wifi network but it works fine with . Sorry we couldn't be helpful. This is the same data as can be sent to the ginlogmonitoring.com website for centralised data collection. Connect one end of an ethernet cable to LAN stickand other end directly to a computer. Select Network, fill in the IP address assigned by the router/network administrator. Or directly download from APP Store or Google Play Store by searching "SolisCloud". Monitoring Accessory Configured But Still Won't Link? 5. Screenshot of the Status page in the configuration interface. You can rerun the wizard and see if that works. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. Continue with Recommended Cookies, Home solis solis S3-WIFI WiFi Stick Datalogger Installation Guide, WiFi Stick Datalogger QuickInstallation ManualVersion: 3.1. Step 6: Plant creation succeeds. If the connection is weak (1-2 bars) then it is recommended to install a. range extender to boost the signal strength where the logger is going to be. 2. Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. Technician check pins 1 and 2 for 5VDC, 3. AC Voltage Offset Procedure and Firmware Requirements, Service - Modbus Issues - Troubleshooting, LCD Protective Sticker Replacement Procedure. No-Grid - El inversor no reconoce la red. We recommend something with a larger screen. View the total data of your PV plant. Note* You can use your phone, tablet or laptop. Wi-Fi communication range: 300m in outdoor open area without obstruction. This new monitoring platform will empower you like never before. No, Modified on: Tue, Oct 25, 2022 at 4:55 PM. Just note that the Freshdesk service is pretty big on some cookies (we love the choco-chip ones), and some portions of Freshdesk may not work properly if you disable cookies. WiFi datalogger firmware is out of date. Data Logging Stick: S2-WL-ST. Support WiFi and LAN communication / Plug and play, quick installation . ContactPlease contact us if you have any technical problems in terms of the product. 1: Connect LAN stick to operational inverter to provide power to LAN stick. In general you want to ensure the router is not blocking the IP address from the WIFI stick. account already, then please follow the steps below to create a plant and commission a Solis, Tap "Create Plant" to finish making a system in, - tap "View Plant" once it gives you a big check mark, When the plant page opens, you will receive a message saying "No datalogger was added, please add a datalogger" tap "Add" if the, data logger is plugged into the bottom of the inverter, A scanner will automatically come up. Once the logger is scanned it will be added to the system. Dataloggers can be scanned or added manually by entering in the serial number. Questions and discussion about solar, batteries, and other renewable energy technology. Manage Settings If the WIFI stick doesn't show a connected inverter check the address of the inverter. AGL replaced the data logger a few months back and it has worked perfectly since then. logger can only connect to 2.4 GHz networks and is unable to connect to 5 GHz networks. An example of data being processed may be a unique identifier stored in a cookie. or, which is default value. ), Get the latest developments in Ginlong Solis, Copyright@2019 Ginlong Technologies All Rights Reserved, Solis_datasheet_S3-GPRS,WiFi-ST_IND_V2.0_2022_08.pdf. 3: Set a manual IP for the computer using the following information -, (The IP of the computer must be with 10.10.100.XXX range to configure the LAN stick). SolisCloud App helps you manage PV plant: 1. Never lost connection since, so yeah you're probably having WiFi range issue. cordless phone, concrete wall, PV panel and metal wall, to ensure the communication quality. Thanks Peter. Step 3: Manually fill in the datalogger SN or Scan the SN on the datalogger. Or directly download from APP Store or Google Play Store by searching SolisCloud. This is to (1) ensure you have the correct, password and (2) ensure there is a strong enough. 1. If you are verifying the connection on m.ginlong.com or pv.ginlong.com please allow 5-10 minutes for the updates to appear. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. signal at the inverter for there to be a stable connection. SolisCloud Step 2: If it is a new data logger, please configure it first, then click the " Willi configure". Note: the logger is unable to connect to any. Solis Data Logging Stick GPRS/WiFi Installation Video Solis 46.7K subscribers 15K views 9 months ago Solis monitoring system is centred around the photovoltaic power station, focusing on. WiFi datalogger firmware is out of date 1. A Solis 5K inverter is used here as an example. Open navigation. SolisCloud intelligent software enables systems to be commissioned, monitored and maintained remotely saving time and money for installers and empowering . logger's local network which allows you to link it to the home network. Insert the datalogger to the inverter COM port. When I am logged into the data logger via wifi the status says that it is connected and when I test the connection on the server page it seems to be all good. Connect the WIFI stick by attaching it to the green plug on the bottom of all Solis inverters. Gua rpida de instalacin del sistema de monitoreo para Mxico y Centro Amrica. Please provide the following information as well: Ginlong Technologies Co., Ltd.No. Data Logger into the port and be sure to secure it by tightening the black connector. This process can also be used to move a Solis Data Logger from one site to another. Verify the RSSI (signal strength) is higher than 15%. Enter the password for the network and then tap "Next". This article is a guide for how to replace a Solis Data Logger on an existing system: one that has already been created in SolisCloud. S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //. Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide Michael Allen Modified on: Tue, Oct 4, 2022 at 2:54 PM. Can AGL please provide some support (a guide that is user friendly in english rather than fractured english) to help me connect and gain access to my PV data. Then click Done. If you have not already been registered on, It is highly recommended to first connect your phone to the home network that you wish to connect the, logger to. Solis Data Logger Server Information - firewall exceptions Modified on Fri, 09 Dec 2022 at 02:15 PM When the network environment of the plant has a firewall, you need to add the server information to the white list of the firewall. The next screen should say "Configuration Complete" and you may tap "OK (3/3)" to finish up the commissioning, The system needs betweenten and fifteen minutesto sendit'sfirst report in, so please wait until the system begins to show data onSolisCloudbefore leaving the site, Did you find it helpful? 125K Multi-Input Inverter: No Paralleled DC Strings Allowed! Solis-(75-100)K-5G-US Solis-125K-EHV-5G Solis-(185-255)K-EHV-5G-US RHI-1P(5-10)K-HVES-5G Data Logging Stick Data Logging Box Cellular Data Logger Case Study Service and Support Download Warranty After-sales Service Monitoring PV Plant Design FAQ Enterprise Explore Newsroom Video Center Event Registration About US Company Profile Copyright@2020 Ginlong Technologies All rights reserved, Data Logger is fairly similar to the Cellular Data Logger's process. 5. We use cookies to try and give you a better experience in Freshdesk. Select Network, fill in the IP address assigned by the router/network administrator, 1: Connect LAN stick to operational inverter to provide power to LAN stick. Connect to the datalogger - AP_XXXXXXXXXX 3. View real-time data of the PV plant , and get equipment condition is controlled at anytime and anywhere. Then plug the. https://www.youtube.com/watch?v=0F0aGeTOYw8. Category: Monitoring and Communication Shows the power supply status of the datalogger. Step 1: Use your phone to scan the QR code to download and register the Solis Cloud APP. Note that all scripts use Python 3. When configured correctly (see below), Solis invertors will send data about their performance every 5 minutes to code waiting to receive the data. Internal DC Short: In the inverter head, or the wirebox? 0:00 / 1:28 Reset instruction for Solis Datalogger Solis 46.7K subscribers Subscribe 130 37K views 3 years ago When the datalogger fails, you can try to reset it to repair. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. Copyright@2019 Ginlong Technologies All rights reserved, Dec-17-2019, Go Solis Webinar: 2020 CA Solar Mandate Compliance with Solis Inverters, Feb-11-2020, Go Solis Webinar: New Solis 125K 1500V Inverters plus AlsoEnergy: Better ROI for 2-40 MW Systems, Mounting, Wiring, and Commissioning 4G Single Phase Inverter - Video, Solis and the Tigo TS4 Platform; Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Contacting Technical Support for Solis Partners, Contacting Technical Support for Your Region, Go Solis 2020 Webinar #7: Testing Solis Inverters Beyond Certifications with PV Evolution Labs, Go Solis Mini Exchange#1: An Introduction to Energy Storage System, Go Solis Webinar #1: 2020 California Solar Mandate with Solis Inverters (12/17/2019, U.S.), Go Solis Webinar #2: The New Solis 125K 1500V Inverters plus Also Energy (2/11/2020, U.S.), Go Solis Webinar #3: Solis Hybrid Energy Storage Inverter with LG Chem (2/11/2020, U.S.), Go Solis Webinar #4: Solis Commercial Inverters (4/21/2020, U.S.), Go Solis Webinar #5: Solis inverters and SunSpec Alliance (5/5/2020, U.S.), Go Solis Webinar #6: Solis and Tigo TS4 Platform - Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Go Solis Webinar #8 Solis Inverters and SunSpec Alliance: The Importance of SunSpec CSIP 2030.5, Ginlong Solis: Standard Lead Time from Ningbo to USA/Canada, How to Determine the Firmware Version of your Solis Inverter, Lowering Output Power of Single Phase Solis Inverter, MA Compatibility Between Single Phase 4G and 2G inverters, Solis 3PH and CSI GS Product Number and Description 20180331, Starting Serial Numbers and HMI VER- ISO-NE / Rule 21 P1 and P3, String Sizing for 1P and 3P Inverters.
Satisfactorily Connects To Earth In A Gathering Movement, They Fought Like Cats And Dogs Metaphor, Volume Change Of Iron From Bcc To Fcc, Articles S